Wobble Stick

Increased Automation/Manual Movements In Vacuum A wobble stick allows movement within a vacuum chamber. Most movements that would typically be done by hand can be done through a wobble stick. For example, in a vacuum under pressure, a wobble stick can move to press a button or rotate an object. While linear actuators only allow movement along one of the three planes, a wobble stick can also introduce movement along all of the planes within an approximately 270-degree cone volume … Read More

High Density, High Count, Thermocouple Port

This High Density, High Count, Thermocouple Port – for 1×10-10 Torr will be of greatest interest to our Altitude Test and Space Simulation customers, who are testing systems requiring an increasing density of sensor connections. It provides for up to 80 thermocouple pairs (comprised of 16 x 5-pair subassemblies) over a 10” diameter footprint. The port allows easy, low-cost maintenance: A single-sensor fault is readily resolved by changing out only the one affected feedthrough subassembly. Upgrading and refurbishing to such … Read More

UHV/HV Manual Vent to Atmosphere Kit

For manual tempered venting of UHV/HV systems. Recommended for use in systems controlled by a VCC to permit venting during power failure. Metering is manually set/adjuated to prevent side-effects of too rapid a vent. NOTE: Ideally, UHV/HV systems should be always be vented to dry inert gas purge even during power failure. See our UHV/HV manual purge kit option. CF or QF flanges Vacuum Break and Metering Valves connected in series. Diffuser

Purge Gas Kits

Purge Kit Selection Control Type VACUUM LEVEL Manual Automated LV Manual LV Vent to Gas Purge Kit Automated LV Vent to Gas Purge UHV/HV Manual UHV/HV Vent to Gas Purge Kit Automated UHV/HV Vent to Gas Purge Kit View Contamination Control Kit » Manual LV Vent to Gas Purge Kit For manual tempered venting to gas purge of LV systems. Ball valve, metering valve, flow regulator, and pressure relief valve Metering is manually set/adjusted Automated LV Vent to Gas Purge … Read More

Cold Finger (LN2)

Placed within the chamber (and operated as the coldest element), the cold finger can augment a HV/UHV pumping system improving chamber pumpdown time by attracting outgassing molecules. Includes: Cryo finger for 77K (-196C) operation, with getter or carbon sleeve 1.5” OD x up to 12” on CF450 flange, or 3” OD x up to 18” on CF600 flange 1/2″ JIC SS braided Cooling supply Lines Cryogenic Connectors Thermocouple CF flange Assembly and Test Required: LN2 supply Thermocouple readout Mating CF … Read More

Pfeiffer Model HiPace 400 Turbo Molecular Pump with TC400 Integrated Controller

Inlet flange: DN 100 CF-F or DN 100 ISO K Exhaust flange: KF25 N2 pumping speed = 355 l/sec H2 pumping speed = 445 l/sec Compression ratio N2 = > 10 11 Compression ratio H2 = 4. 10 5 Run up time = 2. Minutes Max foreline pressure = 11. mbar Operating voltage 48VDC with universal power supply 100VAC-230VAC RS485, front panel display interface, and remote control standard with capability of operating backing pump and fan control Approved for TUV, … Read More

Pfeiffer Model HiPace 80 Turbo Molecular Pump with TC110 Integrated Controller

Inlet flange: DN 63 CF-F or DN 63 ISO K Exhaust flange: KF16 N2 pumping speed = 67 l/sec H2 pumping speed = 48 l/sec Compression ratio N2 = > 10 11 Compression ratio H2 = 9. 10 5 Run up time = 1.75 Minutes Max foreline pressure = 20. mbar Operating voltage 48VDC with universal power supply 100VAC-230VAC RS485, front panel display interface, and remote control standard with capability of operating backing pump and fan control Approved for TUV, … Read More

Pfeiffer Model HiPace 700 Turbo Molecular Pump with TC400 Integrated Controller

Inlet flange: DN 160 CF-F Exhaust flange: KF25 N2 pumping speed = 685 l/sec H2 pumping speed = 555 l/sec Compression ratio N2 = > 10 11 Compression ratio H2 = 4, 10 5 Run up time = 2. Minutes Max foreline pressure = 11. mbar Operating voltage 48VDC with universal power supply 100VAC-230VAC RS485, front panel display interface, and remote control standard with capability of operating backing pump and fan control Approved for TUV, UL, CSA, Semi S2 standards, … Read More

Pfeiffer Model HiPace 1200 Turbo Molecular Pump with TC1200 Integrated Controller

Inlet flange: DN 200 CF-F or DN 200 ISO K Exhaust flange: KF 40 N2 pumping speed = 1250 l/sec H2 pumping speed = 1100 l/sec Compression ratio N2 = > 10 8 Compression ratio H2 = 6. 10 3 Run up time = 2.5 Minutes Max foreline pressure = 2. mbar Operating voltage 48VDC with universal power supply 100VAC-230VAC RS485, front panel display interface, and remote control standard with capability of operating backing pump and fan control Approved for … Read More

Vacuum Hose

Vacuum hose sizes are determined by the system’s pump, size, flanges, and capacity. 1/4″-3/8″-1/2″-3/4″-1 1/2″ ID Vacuum Grade / Heavy Wall Clear Vacuum Hose Also available, stainless steal Vacuum Grade Hoses